PATIENT MONITOR


ICARD L
ICARD L Patient Monitors with 12.1″ displays
Multiparameter monitors, designed for mounting at anesthesia apparatus and for monitoring patients requiring measurement of a greater number of parameters.
Simple operation, extensive self-diagnostic functions and automatic calibration make ICARD L an user-friendly device that guarantees long-term operation at low operating costs
We offer measurement and supervision of the following parameters:
ECG – Three or five-electrode cable. Simultaneous presentation of 1, 2 or 3 leads, measurement of heart rate, acoustic and optical QRS signaling. ST segment elevation measurement, and as an option – arrhythmia analysis.
PULSE OXIMETRY (SpO2) – Measurement with a wide range of sensors, eg on the finger, ear, hand or foot of the child. Measurement of pulse rate in peripheral blood vessels and plethysmogram presentation.
NIBP – Measurement activated manually or automatically. Automatic correction of the cuff inflating pressure, a special measurement algorithm for newborns. A wide range of cuffs – from newborns to obese adults.
IBP – Two-channel measurement using typical disposable transducers. Automatic setting of the scale and initial alarm limits depending on the selected label describing the type of pressure being measured.
CAPNOGRAPHY (CO2) – Side-stream measurement of EtCO2, FiO2 and respiratory rate. Presentation of the breathing wave, apnea supervision, signaling of the occlusion of the sampling line. Sample flow 50 ml/min.
TEMPERATURE – Two-channel measurement using the YSI400 standard probes. Presentation of two temperatures and their difference.
CARDIAC OUTPUT – Based on impedance cardiography, non-invasive measurement of Cardiac Otput (CO), Cardiac Index (CI), Stroke Volume (SV) and nine other haemodynamic parameters. Read more
MAINSTREAM GAS MONITORING – External multigas analyzer measuring carbon dioxide (CO2), nitrous oxide (N2O) and five anaesthetic agents with dual agent identification capabilities.
SIDESTREAM GAS MONITORING – Internal multigas analyzer measuring carbon dioxide (CO2), nitrous oxide (N2O), oxygen (O2 – paramagnetic method) and five anaesthetic agents with dual agent identification capabilities. Sample flow 50 ml/min.
DEPTH OF ANAESTHESIA – similar to BIS, determined on the basis of EEG analysis, qCON index on a scale of 0-100. Optionally, the second parameter – the nociception index qNOX.
Multiparameter monitors ICARD L
Designed to monitor the basic vital parameters of the patient in the ICU
Characteristic features:
● case dimensions (without holder): – 312 x 282 x 132 mm
● weight: – about 3,8 kg
● display: – 12,1” LED backlit
● display resolution: – 1024 x 768 pixels (XGA)
● battery operation time: – 3 – 3.5 hours, depending on the operation mode
● mounting: – VESA 75
Measurement module
Electrocardiography (ECG)
Cable with three or five electrodes
Presentation of 3 of 7 leads: I, II, III, aVR, aVL, aVF, Vx (with a
five-electrode cable)
Heart rate
ST segment analysis
Arrythmia analysis
Impedance measurement of breathing parameters
Breathing rate
Respirogram
Pulse oximetry
Pulse rate
Oxygenation ( SpO)
Perfusion Index (PI)
Plethysmogram
NIBP
Presentation of the values of SYS, DIA, MEAN pressure
Measurement algorithms for adults, children and newborns
Invasive blood pressure measurement (two- channel IBP)
Presentation of the values of SYS, DIA, MEAN pressures
Pressure waves P1, P2
Labels describing the pressure wave: P, ART, CVP, PA, ICP, UAC, UV
Side stream capnography (sampling flow 50 ml / min.)
EtCO2, FiCO, respiration rate
Capnogram
Thermometry (two-channel)
Skin or deep temperatures (depends on sensors type)
Calculation of ΔT
Options
Communication module with the central station 2.4 GHz wireless connection
Mainstream capnography insteadof sidestream