STEAM STERILIZER


Autoclave – Floor / TC – A Type
Safety Devices :
The steam sterilizer is a highly safe sterilizing product with stable function, suitable for major hospitals, clinics and biomechanical research laboratories etc., for the sterilization of instrument cloth, glassware and liquid etc.
Practical Sterilization Function :
Operating system
Steam exhaust value outer chamber
YES
Dry Valve inner chamber
The inner chamber is designed to be made #305 stainless steel, and the outer chamber and the door cover is to be made of #304 stainless steel, and the outer layer will be separated by thermal insulation wool for heat preservation. The outside is covered by rectangular stainless steel sheets which provides a more aesthetic appearance and heat preservation.
Stainless steel door with radial lever can effectively lock the door cover tightly and prevent steam leakage.
Silicone door gasket is high-temperature resistant, durable, and without deformation.
The chamber body is supported by a stainless steel support, and the height of level can be adjusted from the adjustable footpad of support base.
1. Preset Vacuum function is able to shorten the sterilization time.
2. Vacuum drying function is able to remove unwanted moisture quickly, and to reach the Bowie Dick test criteria.
3. Cloth / apparatus / Liquid, Sterilization Functional Switch Mode can be selected to switch according to different kind of materials to be sterilized.
4. Auto Water Supply Device : Electrical control system is able to detect and sense the water volume automatically. Use equipment for soft water purification can prolong the life cycle of sterilizer.
1. Auto Power-Off Protection Device for water shortage, when water runs out, the electrical control system will automatically out off the heating power to prevent heating device from overheating, dry-out or even meltdown.
2. Pressure controller, the maximum pressure in the boiler is limited to 2.2 ±0.1kg/cm². When the pressure reaches the set value, the heating power will be automatically off to prevent the pressure from rising.
3. Safety valve, when the pressure reaches 2.8 kg/cm², it will start exhaust of steam and release the pressure from the chamber.
4. Pressure lock, when the pressure of inner chamber exceeds 0.2 kg/cm², the clutch will be locked automatically, and the door cover will not be able to be opened, in order to keep the operator safe.
5. Safety switch of Door Cover, when the door cover is opened the steam in the outer chamber is unable to enter the inner chamber. It cannot be operated normally unless the door cover is closed tightly.
Manual drying function
Automatic drying function
Automatic and Vacuum Drying Function
YES
YES
YES
YES
YES
Dry Function
MANUAL
AUTO
AUTO
Sterilization function
MANUAL
AUTO
AUTO
Thermometer, inner chamber
YES
N/A
N/A
Temperature controller
N/A
YES
YES
Timer
60Minutes
90Minutes
99Minutes
Safety Valve
1 Pcs
1 Pcs
1 Pcs
Pre-heating function
YES
YES
YES
Auto Water Filling
Optional
Optional
YES
Vacuum drying (Pre-vacuum)
N/A
N/A
YES
Glass & liquid sterilization Function
N/A
Optional
YES
Low water Indication / cut-off
YES
YES
YES
Water level control & protection
YES
YES
YES
Safety door lock activated by pressure
Optional
Optional
Optional
Chamber material stainless steel #316 (standard#304)
Optional
Optional
Optional
Trail Cart
Optional
Optional
Optional
Satinless steel tray
1 Pcs
1 Pcs
1 Pcs