STEAM STERILIZER

Autoclave – Floor / TC – A Type

Safety Devices :

The steam sterilizer is a highly safe sterilizing product with stable function, suitable for major hospitals, clinics and biomechanical research laboratories etc., for the sterilization of instrument cloth, glassware and liquid etc.

Practical Sterilization Function :

Operating system

Steam exhaust value outer chamber

YES

Dry Valve inner chamber

The inner chamber is designed to be made #305 stainless steel, and the outer chamber and the door cover is to be made of #304 stainless steel, and the outer layer will be separated by thermal insulation wool for heat preservation. The outside is covered by rectangular stainless steel sheets which provides a more aesthetic appearance and heat preservation.

Stainless steel door with radial lever can effectively lock the door cover tightly and prevent steam leakage.

Silicone door gasket is high-temperature resistant, durable, and without deformation.

The chamber body is supported by a stainless steel support, and the height of level can be adjusted from the adjustable footpad of support base.

1. Preset Vacuum function is able to shorten the sterilization time.

2. Vacuum drying function is able to remove unwanted moisture quickly, and to reach the Bowie Dick test criteria.

3. Cloth / apparatus / Liquid, Sterilization Functional Switch Mode can be selected to switch according to different kind of materials to be sterilized.

4. Auto Water Supply Device : Electrical control system is able to detect and sense the water volume automatically. Use equipment for soft water purification can prolong the life cycle of sterilizer.

1. Auto Power-Off Protection Device for water shortage, when water runs out, the electrical control system will automatically out off the heating power to prevent heating device from overheating, dry-out or even meltdown.

2. Pressure controller, the maximum pressure in the boiler is limited to 2.2 ±0.1kg/cm². When the pressure reaches the set value, the heating power will be automatically off to prevent the pressure from rising.

3. Safety valve, when the pressure reaches 2.8 kg/cm², it will start exhaust of steam and release the pressure from the chamber.

4. Pressure lock, when the pressure of inner chamber exceeds 0.2 kg/cm², the clutch will be locked automatically, and the door cover will not be able to be opened, in order to keep the operator safe.

5. Safety switch of Door Cover, when the door cover is opened the steam in the outer chamber is unable to enter the inner chamber. It cannot be operated normally unless the door cover is closed tightly.

Manual drying function

Automatic drying function

Automatic and Vacuum Drying Function

YES

YES

YES

YES

YES

Dry Function

MANUAL

AUTO

AUTO

Sterilization function

MANUAL

AUTO

AUTO

Thermometer, inner chamber

YES

N/A

N/A

Temperature controller

N/A

YES

YES

Timer

60Minutes

90Minutes

99Minutes

Safety Valve

1 Pcs

1 Pcs

1 Pcs

Pre-heating function

YES

YES

YES

Auto Water Filling

Optional

Optional

YES

Vacuum drying (Pre-vacuum)

N/A

N/A

YES

Glass & liquid sterilization Function

N/A

Optional

YES

Low water Indication / cut-off

YES

YES

YES

Water level control & protection

YES

YES

YES

Safety door lock activated by pressure

Optional

Optional

Optional

Chamber material stainless steel #316 (standard#304)

Optional

Optional

Optional

Trail Cart

Optional

Optional

Optional

Satinless steel tray

1 Pcs

1 Pcs

1 Pcs